TOAST - quantification of Turbo-QUASAR data

Overview

TOAST is a pipeline designed to quantify the hemodynamic parameters of Turbo-QUASAR data. Turbo-QUASAR is a PASL based technique that improves upon the SNR of QUASAR using multiple labelling pulses while preserving the application of crushing gradients and the Look-Locker readout multi-TI acquisition in QUASAR. Each labelling pulse creates a sub-bolus, and the duration of each sub-bolus is equal to the time between each acquisition under optimal blood flow velocity. TOAST uses full Turbo-QUASAR data to produce perfusion in absolute units as well as arterial transit time and ABV images. TOAST also include the option to correct MT effects and estimate the duration of sub-boluses.

More information on the model used can be found in:

Zhao M Y, Václavů L, Petersen E T, Biemond B J, Sokolska M J, Suzuki Y, Thomas D L, Nederveen A J, Chappell M A, (2019). Quantification of Cerebral Perfusion and Cerebrovascular Reserve Using Turbo-QUASAR Arterial Spin Labeling MRI. Magnetic resonance in medicine. https://doi.org/10.1002/mrm.27956

Chappell, M. A., Woolrich, M. W., Petersen, E. T., Golay, X., & Payne, S. J. (2012). Comparing model-based and model-free analysis methods for QUASAR arterial spin labeling perfusion quantification. Magnetic resonance in medicine. doi:10.1002/mrm.24372

E. T. Petersen, J. B. De Vis, C. a. T. van den Berg, and J. Hendrikse, “Turbo-QUASAR: a signal-to-noise optimal arterial spin labeling and sampling strategy,” Proc. Intl. Soc. Mag. Reson. Med. 21 2146., vol. 60, no. 6, p. 2146, 2013.

Turbo-QUASAR Description

As an improvement of the QUASAR method, Turbo-QUASAR was designed to overcome the low SNR of PASL when compared to PCASL by applying a series of labeling pulses to create a longer effective bolus duration. These labeling pulses are inserted between readout (also replacing the QUIPPS II pulse used in QUASAR) to maintain the magnetization level of the tracer for a longer period than conventional PASL techniques, thus increasing the overall SNR of the resulting ASL data. The figure below shows the different labeling techniques and the associated arterial input function for QUASAR, Turbo-QUASAR, and PCASL.

_images/Turbo_QUASAR_description.png

Magnetisation Transfer (MT) effects in Turbo-QUASAR

Due to the RF pulses in the label and control experiments of Turbo-QUASAR, MT effects could potentially affect the estimation accuracy of CBF. Turbo-QUASAR uses Look-Locker readout and the spins follows a saturation recovery. The figure below shows the saturation recovery curve for spins at different locations of the brain. The dash line indicates the time point that the labeling stopped. In essence, the MT effects have a stronger influence to spins that are closer to the labeling region. A correction method has been implemented in TOAST to correct the MT effects by modeling the saturation recovery signal in two parts: (1) under the influence of MT effects and (2) without the influence of MT effects. The correction is achieved by executing the –infert1 option (default).

_images/Turbo_QUASAR_MT_effects.png

User Guide

Usage

TOAST expects the input data without label-control subtraction being performed. A typical command line usage would be:

toast -i <asl_data> -o <output_directory>  --infert1

This would carry out a model-based analysis of Turbo-QUASAR data and provide voxelwise quantification of perfusion and arterial transit time. Note: the current implementation of TOAST does NOT support dispersion correction, model-free analysis, or partial volume correction.

Output files

File name Description
ABV_absolute Arterial blood volume (in decimals) after calibration
Arrival_time_blood Arterial arrival time (in seconds) to macrovasculature
ATT Arterial transit time (in seconds)
calib_M0t M0 of tissue
CBF_absolute CBF (in ml/100g/min) in absolute units after calibration
M0a_for_absolute_CBF M0 of arterial blood used for calibration
mask Mask used in the analysis
T1_tissue T1 (in seconds) of tissue

Sequence parameters

A number of parameters are similar with QUASAR so users may wish to consult the user guide of QUASIL. Only the sequence parameters unique to Turbo-QUASAR are explained here.

--shift Slice shifting factor to increase the effective temporal resolution. Default: 2
--break_1 Slice number of first acquisition point (start from 0). Default: 0
--break_2 Slice number of middle acquisition point (start from 0). Default: 7
--break_3 Slice number of last acquisition point (start from 0). Default: 14
--taupat Specify the pattern of Turbo-QUASAR labeling pulses. Label: 1, no label: 0. Default: 1, 1, 1, 1, 1, 1, 1.

Extended options

These options include the estimation of T1 of tissue, correcting the partial volume effects of the calibration data, and estimation of the arterial blood volume.

--infert1 Estimate voxelwise T1 of tissue
--calib Include a calibration image
--tr TR (in seconds) of the calibration image. Default: 5.0 seconds.
--struct Include a structural image
--corrcal Includecorrection for partial volume effects present around the edges of the calibration image.
--inferart Estimate voxelwise arterial blood volume (ABV or aCBV)